Part of: Monitor & connect

In development. Not live yet: you are pre-ordering.

A PLC alarm at 2 a.m. reaches someone who answers.

Voltrus Alerts takes alarms from your PLCs, SCADA and MQTT topics and sends them to Telegram, WhatsApp, email or a phone call. If nobody acknowledges, it goes to the next person on the on-call roster.

Your $19 pays for your first month when the service opens. Full refund on request until then, and automatically if it is not live by 31 March 2027.

$19
Per site, per month
4 channels
Telegram, WhatsApp, email, phone call
31 March 2027
Live by then, or a full refund
Example escalation (design preview)
  1. Alarm Boiler 2 drum level low: 18 % (limit 25 %). Priority 1.
  2. Telegram Sent to Andi (on call this week)
  3. Phone call No acknowledgement after 5 min: calling Andi
  4. Escalated Calling Budi (shift supervisor)
  5. Acknowledged Budi pressed 1 on the call. Escalation stopped.
  6. Cleared Level back to 31 %. Everyone notified is told.

From a tag value to a person who knows about it

01

Connect a source

An MQTT topic on your Voltrus Broker or another broker, an HTTPS webhook, or tags polled by Voltrus Gateway at the site.

02

Define the alarm

High and low limits with a deadband, or a bit that means fault. Add on and off delays so a flickering value does not page anyone.

03

Set the roster

Who is on call this week, who comes next, and how long to wait between steps.

04

Escalate until acknowledged

The first person gets a message. No answer, and the next step runs: a phone call, then the supervisor.

05

Keep the record

Every alarm, message, delivery result and acknowledgement is logged with a time, ready to export as CSV.

Four ways to reach the person on call

Each priority gets its own channels: a low-priority alarm can go to email only, a priority 1 alarm to Telegram first and a phone call after five minutes.

01

Telegram

A message from the Voltrus Alerts bot with an Acknowledge button. Unlimited.

02

WhatsApp

A WhatsApp Business message; reply ACK to acknowledge. 200 messages per site per month planned in the price.

03

Email

One email per alarm with an acknowledge link. Unlimited.

04

Phone call

A voice call reads the alarm out; press 1 to acknowledge. 20 calls per site per month planned in the price.

What version 1 will do, and what it will not

This is the scope we are building against. If a pre-order customer needs something outside it, tell us before launch.

How alarms get in

  • MQTT: Voltrus Alerts subscribes to topics you choose on your Voltrus Broker, or on another broker reachable over TLS (MQTT 3.1.1 or 5). The value is the payload, or a field in a JSON payload.
  • Webhook: an HTTPS POST to a per-site URL with a secret token, carrying the alarm name, state (active or cleared), value and text. Voltrus SCADA notifications, Voltrus Broker webhook rules, a RustRED or Node-RED http request node, or any script can send it.
  • Polling through Voltrus Gateway: a small Alerts agent runs next to the Gateway at the site, subscribes to tags over Modbus TCP, BACnet/IP (HVAC and building alarms), S7, OPC UA, EtherNet/IP or DNP3, and sends changes out over HTTPS. It needs no inbound port. Modbus RTU needs a serial-to-TCP converter.

Alarm rules

  • High and low limits with a deadband, and digital alarms on a bit or boolean.
  • On delay and off delay per alarm.
  • Three priorities, each with its own channels and escalation policy.
  • States: active, acknowledged, cleared. An alarm that cleared before anyone acknowledged it stays open until someone does.
  • Site heartbeat: if a source or the Gateway agent goes silent for longer than you set, Alerts raises a "site not reporting" alarm.

Escalation, roster and acknowledgement

  • An escalation policy is a list of steps: who, which channel, how many minutes to wait. It repeats until someone acknowledges or the steps run out.
  • On-call roster with a weekly rotation and one-off overrides for leave and swaps, in the site time zone.
  • Acknowledge from the Telegram button, a WhatsApp reply, the email link, by pressing 1 on the call, or in the web console. The first acknowledgement stops the escalation and everyone already notified sees who took it.
  • Messages in English or Indonesian.

Not in version 1

  • SMS.
  • Writing back to the PLC (no remote reset or acknowledge in the PLC).
  • Sparkplug B payload decoding.
  • Shelving and the full ISA-18.2 state model.
  • Installing Voltrus Alerts on your own server: v1 is hosted only.
  • Use as a fire alarm, gas detection or any life-safety system. Voltrus Alerts is a notification service and does not replace them.

Part of: Monitor & connect · See the plant: dashboards and alarms, machine OEE, remote access, messaging.

How Voltrus Alerts differs from…

  • Voltrus SCADA

    Voltrus SCADA evaluates alarms on your own server and can send email, webhook, Telegram and WhatsApp notices. Alerts adds the on-call roster, escalation and phone calls, and can take alarms from SCADA by webhook.

  • Voltrus Broker

    Voltrus Broker carries the MQTT messages and can fire a webhook when a rule matches. Alerts keeps alarm state, waits for an acknowledgement and escalates.

  • Voltrus Gateway

    Voltrus Gateway reads PLC tags over seven protocols. With the Alerts agent beside it, those tags become alarm sources without an inbound port.

Not sure? See which one you need →

Against the alarm notifiers plants buy today

Prices are the published starting prices we found in November 2026. Check the vendors for current terms.

Voltrus Alerts
WIN-911
Ignition Alarm Notification
Price
$19 per site per month
From $3,300 per 3 years
From $1,700
Telegram
Yes
Not listed
Not listed
Phone call, email
Yes
Yes
Yes (voice is an add-on)
Where it runs
Hosted, with an agent at the site for polling
Installed software
A module on an Ignition gateway
Status
In development (pre-order)
Shipping
Shipping

One price per site

  • You pay $19 once now, by card. It covers your first month when the service opens.
  • Founding customers keep this price for as long as they stay subscribed.
  • Full refund on request any time before your first month starts. If Voltrus Alerts is not live by 31 March 2027, we refund you without being asked.

Card payment in USD through Polar. Rupiah and QRIS payment will be available when the service opens.

Common questions

No. We are taking pre-orders to check that plants want it before we build it. Pre-order customers are the first to get access and help us decide what comes after v1. If it is not live by 31 March 2027, every pre-order is refunded.
You get a receipt from Polar and a Voltrus console account under the same email. We email you when your site can be set up. Your paid month starts on the day you get access, not on the day you pay.
No. Any system that can send an HTTPS webhook or publish to an MQTT broker over TLS works. Voltrus Gateway is only needed if you want Alerts to poll PLC tags directly.
Anything that reaches Voltrus Alerts through MQTT or a webhook. Through Voltrus Gateway: Modbus TCP, BACnet/IP, Siemens S7, OPC UA, EtherNet/IP and DNP3 devices.
Alerts cannot reach the site, so it cannot see new alarms. The heartbeat check notices the silence and alerts the roster that the site is not reporting.
No. Voltrus Alerts is a notification service for process and equipment alarms. It does not replace a certified fire alarm, gas detection or safety system.
The pre-order is card only ($19). When the service opens, the monthly price is Rp 299.000 and you can pay by QRIS or saldo in the Voltrus console.

Get your alarms to someone who can act on them

Pre-order now for $19. It pays your first month, and you can get your money back any time until launch.

Stay Updated

Get notified about Voltrus Alerts

Not ready to pre-order? Leave your email and we will tell you when it opens.