Emerson Daniel 1000 simulator template: register layout

The register layout the Modbus Poll slave simulator uses for a Emerson Daniel 1000: Gas Flow Computer (orifice meter, AGA3/AGA8). This is a test layout built into the app, not the manufacturer's own register map.

This is a test layout, not the manufacturer's register map. It is the layout the slave simulator in Modbus Poll uses so you can practise and test a SCADA or script without the real device. A real Emerson Daniel 1000 uses different addresses.

Protocol
Modbus TCP (simulator)
Addresses in the manual
0-based protocol addresses, as sent on the wire
32 and 64-bit values
High word first (AB CD)
Registers listed
11
Source
voltrus-explorers apps/modbus-poll/src/templates.ts at commit 1933046

Address base. Addresses are the 0-based wire addresses Modbus Poll uses. The simulator packs the values one after another from the base address. Address 3000 in the manual is address 3000 on the wire.

Word order. The simulator writes 32-bit floats with the high word first and 64-bit counters as big-endian doubles over four registers.

Modbus Poll and the Modbus protocol itself count from 0. The "Wire address" column is the number to type into Modbus Poll.

Downloads

The register table has every column on this page. The blocks file imports into Modbus Poll. The template JSON holds the same blocks plus unit, scale and access for scripts.

Registers

11 registers
Manual Wire Register Type Regs Unit Scale Access Area
3000 3000 Orifice differential pressureDiff_Pressure · Simulated value, starts near 85. float32 2 inH2O 1 RW Holding (FC03)
3002 3002 Line static pressureStatic_Pressure · Simulated value, starts near 745. float32 2 psig 1 RW Holding (FC03)
3004 3004 Gas temperatureTemperature · Simulated value, starts near 95. float32 2 °F 1 RW Holding (FC03)
3006 3006 Instantaneous gas flow rateFlow_Rate · Simulated value, starts near 1250. float32 2 MSCFH 1 RW Holding (FC03)
3008 3008 Accumulated gas volume todayVolume_Today · Counter: the simulator increases it over time. float64 4 MSCF 1 RW Holding (FC03)
3012 3012 Lifetime accumulated volumeVolume_Total · Counter: the simulator increases it over time. float64 4 MMSCF 1 RW Holding (FC03)
3016 3016 Specific gravity (air=1)Gas_Gravity · Simulated value, starts near 0.62. float32 2 1 RW Holding (FC03)
3018 3018 Higher heating valueHeating_Value · Simulated value, starts near 1025. float32 2 BTU/SCF 1 RW Holding (FC03)
3020 3020 Methane fractionCH4 · Simulated value, starts near 88.5. float32 2 mol% 1 RW Holding (FC03)
3022 3022 Carbon dioxide fractionCO2 · Simulated value, starts near 1.8. float32 2 mol% 1 RW Holding (FC03)
3024 3024 Hydrogen sulfideH2S · Simulated value, starts near 12. float32 2 ppm 1 RW Holding (FC03)

Scale is the number to multiply the raw value by to get the unit. Types with more than one register (32 and 64-bit) follow the word order above.

Open in Modbus Poll

  1. Download the Modbus Poll blocks file.
  2. Open Modbus Poll, connect to the device and set its unit ID. In Modbus Poll set Word order to AB CD.
  3. In the blocks panel on the right, click Import CSV and pick the file. CSV import is a Pro feature. Without Pro, Modbus Poll polls the first 20 values of your blocks.
  4. The wire addresses are already in the file, so there is no 0-based or 1-based conversion to do.

Once the values look right, export the tag list to Ignition, Kepware, Node-RED, Home Assistant or Voltrus SCADA.

Source and accuracy

Source: Modbus Poll source code, device templates (github.com)

voltrus-explorers apps/modbus-poll/src/templates.ts at commit 1933046. Read on 2026-10-24.

This layout is part of the open source Modbus Poll app.

Found a mistake? Report it by email with the register address and the manual page.

All register maps · Modbus addressing explained