CNC Explorer Documentation

Installation

CNC Explorer is a native macOS app, not on the Mac App Store. Download the notarized DMG, open it, and drag the app to Applications.

Download

System Requirements

RequirementMinimum
macOS13 Ventura or newer (Apple Silicon and Intel)
MTConnectAn agent reachable over HTTP (MTConnect 1.x or 2.x documents)
FANUCA controller with the Ethernet function enabled, reachable on TCP port 8193 (Beta)

Licence activation needs an internet connection once. Afterwards the app works offline.

Quick Start

1. Connect to an MTConnect agent

  1. Set Connection type to MTConnect agent.
  2. Enter the agent URL, for example http://localhost:5000. Leave Device empty for all devices, or name one.
  3. Connect. The Data, Conditions, Devices and Assets tabs fill from the agent's probe, current, sample and assets documents.

2. Connect to a FANUC controller (Beta)

  1. Set Connection type to FANUC (FOCAS/Ethernet) Beta.
  2. Enter the controller's host and port (default 8193).
  3. Use Overview, Axes, Program, Alarms, Macros and Parameters, diagnosis, PMC to read the machine.
The FANUC path has been tested against the built-in simulator and the pyfanuc reference client, and never against a real controller. Start with reads only.

Configuration

ConnectionFieldDefault
MTConnectAgent URLhttp://localhost:5000
MTConnectTimeout / stream interval10000 ms / 500 ms
FANUCHost / port192.168.1.100 / 8193
FANUCTimeout / poll interval5000 ms / 1000 ms

The free version keeps one saved profile and streams 10 MTConnect items live. Pro removes both limits.

Simulators (Pro)

Switch Mode to Simulator. The agent simulator serves /probe, /current, /sample and /assets for a 3-axis VMC or a 2-axis lathe, with an optional SHDR adapter port (default HTTP 5000, SHDR 7878). The CNC simulator answers FOCAS/Ethernet requests with a 31i-B or 0i-F identity (default port 8193). Connect the client to 127.0.0.1 to try either. The simulator's identity strings and parameter, diagnosis and PMC values are made up, not recorded from hardware.

Troubleshooting

  • Agent does not connect: open the agent URL in a browser on the same Mac. If it fails there, check the network and firewall.
  • FANUC times out: confirm the Ethernet function is on, the IP is reachable and port 8193 is open. Raise the timeout on slow links.
  • Licence key rejected: enter it with its dashes, with internet access for the first activation. See Support.

Support

Email [email protected] or see the support page. FANUC and FOCAS are trademarks of FANUC Corporation; MTConnect is a trademark of AMT. Voltrus is not affiliated with either.