  "format": "voltrus-device-template/1",
  "template_id": "jk-bms-rs485-modbus",
  "manufacturer": "JK BMS",
  "model": "RS485 general protocol V1.1",
  "protocol": "modbus",
  "description": "Modbus RTU over RS485 protocol of JK BMS (JIKONG, Chengdu Jikong Technology) battery management systems. The document is a general protocol and does not list product models; the vendor's download page names V1.0 for firmware V11.36. It defines four register blocks: settings at 0x1000, live data at 0x1200, device information at 0x1400 and write only commands at 0x1600. Per-cell values, protection thresholds, alarms, SOC and capacity are listed. The document also lists the per-cell connection and balance wire resistance registers, the protocol selection registers and the voltage and current calibration commands, but this file leaves them out. Register map: https://voltrus.id/registers/jk-bms/rs485-modbus/",
  "version": "1.0.0",
  "verified": false,
  "verified_notes": "Generated by voltrus.id from Document 'Jikong BMS RS485 Modbus general protocol (V1.1)', Chengdu Jikong Technology Co., Ltd, dated 2024.02, revision record V1.1 2024.01 (fixes some errors and adds registers), 15 pages. The vendor hosts this document on its own site at http://www.jk-bms.com/Upload/2024-02-21/1345398693.pdf (http only, the https form did not respond). The linked https copy is hosted by JKVOLT (jkvolt.com, which describes itself as an authorized JK BMS distributor operated by Chengdu JK Volt Technology Co., Ltd.) on its download center page, served from the Shopify CDN. The two files are byte-identical (same SHA-256, b9b3f1e4...d22739), and a third copy on the jkbms.net downloads archive is also identical. Field names are in English and descriptions are Chinese, so labels here are translations; the document field name is given in every note. (https://cdn.shopify.com/s/files/1/0709/3338/1309/files/BMS_RS485_Modbus_V1.1_7dda8b75-5c6e-4ddb-99ff-fb4b4cd1e1cc.pdf), read 2026-10-24. Not checked against a real device; confirm a known value before relying on it.",
  "quirks": [
    "Offsets are 0-based wire addresses. The manual prints 0-based addresses, the same as here.",
    "Word order from the manual: High word first (AB CD).",
    "The write examples on p. 14 show the 32-bit value 3540 (3.54 V, VolSmartSleep) sent as 00 00 0D D4, and -250 (0.1 degC units) as FF FF FF 06, so the high word comes first. The document gives no example for float values.",
    "The device speaks Modbus RTU over RS485. Voltrus SCADA polls Modbus TCP, so connect it through a Modbus RTU to TCP gateway: use the gateway's IP and port and the device's unit ID.",
    "Defaults from the manual: 115200 baud, 8 data bits, no parity, 1 stop bit; slave addresses 1 to 247; function codes 03H (read registers) and 10H (write registers) (p. 3). The slave address is held in the DevAddr setting.",
    "43 unsigned 32-bit registers are read as int32: exact up to a raw value of 2,147,483,647.",
    "Not included, because templates have no 64-bit integer or string type: Manufacturer_Device_Id, Hardware_Version, Software_Version."
  ],
  "license": "CC-BY-4.0",
  "port": 502,
  "unit_id": 1,
  "interval_ms": 1000,
  "endianness": "big",
  "registers": [
    {
      "name": "Smart_Sleep_Voltage",
      "offset": 4096,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Voltage to enter smart sleep (manual address 4096)",
      "writable": true
    },
    {
      "name": "Cell_Undervoltage_Protection",
      "offset": 4100,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell undervoltage protection (manual address 4100)",
      "writable": true
    },
    {
      "name": "Cell_Undervoltage_Recovery",
      "offset": 4104,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell undervoltage protection recovery (manual address 4104)",
      "writable": true
    },
    {
      "name": "Cell_Overcharge_Protection",
      "offset": 4108,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell overcharge protection voltage (manual address 4108)",
      "writable": true
    },
    {
      "name": "Cell_Overcharge_Recovery",
      "offset": 4112,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell overcharge protection recovery voltage (manual address 4112)",
      "writable": true
    },
    {
      "name": "Balance_Trigger_Difference",
      "offset": 4116,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage difference that triggers balancing (manual address 4116)",
      "writable": true
    },
    {
      "name": "Soc_100_Voltage",
      "offset": 4120,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "SOC 100% voltage (manual address 4120)",
      "writable": true
    },
    {
      "name": "Soc_0_Voltage",
      "offset": 4124,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "SOC 0% voltage (manual address 4124)",
      "writable": true
    },
    {
      "name": "Recommended_Charge_Voltage",
      "offset": 4128,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Recommended charge voltage (manual address 4128)",
      "writable": true
    },
    {
      "name": "Float_Charge_Voltage",
      "offset": 4132,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Float charge voltage (manual address 4132)",
      "writable": true
    },
    {
      "name": "Auto_Shutdown_Voltage",
      "offset": 4136,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Automatic shutdown voltage (manual address 4136)",
      "writable": true
    },
    {
      "name": "Continuous_Charge_Current",
      "offset": 4140,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Continuous charge current (manual address 4140)",
      "writable": true
    },
    {
      "name": "Charge_Overcurrent_Delay",
      "offset": 4144,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Charge overcurrent protection delay (manual address 4144)",
      "writable": true
    },
    {
      "name": "Charge_Overcurrent_Release_Delay",
      "offset": 4148,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Charge overcurrent protection release delay (manual address 4148)",
      "writable": true
    },
    {
      "name": "Continuous_Discharge_Current",
      "offset": 4152,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Continuous discharge current (manual address 4152)",
      "writable": true
    },
    {
      "name": "Discharge_Overcurrent_Delay",
      "offset": 4156,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Discharge overcurrent protection delay (manual address 4156)",
      "writable": true
    },
    {
      "name": "Discharge_Overcurrent_Release_Delay",
      "offset": 4160,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Discharge overcurrent protection release delay (manual address 4160)",
      "writable": true
    },
    {
      "name": "Short_Circuit_Release_Delay",
      "offset": 4164,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Short circuit protection release delay (manual address 4164)",
      "writable": true
    },
    {
      "name": "Max_Balance_Current",
      "offset": 4168,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Maximum balance current (manual address 4168)",
      "writable": true
    },
    {
      "name": "Charge_Overtemperature_Protection",
      "offset": 4172,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Charge over-temperature protection (manual address 4172)",
      "writable": true
    },
    {
      "name": "Charge_Overtemperature_Recovery",
      "offset": 4176,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Charge over-temperature recovery (manual address 4176)",
      "writable": true
    },
    {
      "name": "Discharge_Overtemperature_Protection",
      "offset": 4180,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Discharge over-temperature protection (manual address 4180)",
      "writable": true
    },
    {
      "name": "Discharge_Overtemperature_Recovery",
      "offset": 4184,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Discharge over-temperature recovery (manual address 4184)",
      "writable": true
    },
    {
      "name": "Charge_Undertemperature_Protection",
      "offset": 4188,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Charge low-temperature protection (manual address 4188)",
      "writable": true
    },
    {
      "name": "Charge_Undertemperature_Recovery",
      "offset": 4192,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Charge low-temperature recovery (manual address 4192)",
      "writable": true
    },
    {
      "name": "Mos_Overtemperature_Protection",
      "offset": 4196,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "MOS over-temperature protection (manual address 4196)",
      "writable": true
    },
    {
      "name": "Mos_Overtemperature_Recovery",
      "offset": 4200,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "MOS over-temperature protection recovery (manual address 4200)",
      "writable": true
    },
    {
      "name": "Cell_Count",
      "offset": 4204,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Number of cells (manual address 4204)",
      "writable": true
    },
    {
      "name": "Charge_Enable",
      "offset": 4208,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Charge switch (manual address 4208)",
      "writable": true
    },
    {
      "name": "Discharge_Enable",
      "offset": 4212,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Discharge switch (manual address 4212)",
      "writable": true
    },
    {
      "name": "Balance_Enable",
      "offset": 4216,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Balance switch (manual address 4216)",
      "writable": true
    },
    {
      "name": "Battery_Design_Capacity",
      "offset": 4220,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mAh",
      "description": "Battery design capacity (manual address 4220)",
      "writable": true
    },
    {
      "name": "Short_Circuit_Delay",
      "offset": 4224,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "us",
      "description": "Short circuit protection delay (manual address 4224)",
      "writable": true
    },
    {
      "name": "Balance_Start_Voltage",
      "offset": 4228,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Balance start voltage (manual address 4228)",
      "writable": true
    },
    {
      "name": "Device_Address",
      "offset": 4360,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Device address (slave address) (manual address 4360)",
      "writable": true
    },
    {
      "name": "Discharge_Precharge_Time",
      "offset": 4364,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Discharge precharge time (manual address 4364)",
      "writable": true
    },
    {
      "name": "Setting_Flags",
      "offset": 4372,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Settings flag bits (manual address 4372)",
      "writable": true
    },
    {
      "name": "Cell_Voltage_0",
      "offset": 4608,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 0 (manual address 4608)"
    },
    {
      "name": "Cell_Voltage_1",
      "offset": 4610,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 1 (manual address 4610)"
    },
    {
      "name": "Cell_Voltage_2",
      "offset": 4612,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 2 (manual address 4612)"
    },
    {
      "name": "Cell_Voltage_3",
      "offset": 4614,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 3 (manual address 4614)"
    },
    {
      "name": "Cell_Voltage_4",
      "offset": 4616,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 4 (manual address 4616)"
    },
    {
      "name": "Cell_Voltage_5",
      "offset": 4618,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 5 (manual address 4618)"
    },
    {
      "name": "Cell_Voltage_6",
      "offset": 4620,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 6 (manual address 4620)"
    },
    {
      "name": "Cell_Voltage_7",
      "offset": 4622,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 7 (manual address 4622)"
    },
    {
      "name": "Cell_Voltage_8",
      "offset": 4624,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 8 (manual address 4624)"
    },
    {
      "name": "Cell_Voltage_9",
      "offset": 4626,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 9 (manual address 4626)"
    },
    {
      "name": "Cell_Voltage_10",
      "offset": 4628,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 10 (manual address 4628)"
    },
    {
      "name": "Cell_Voltage_11",
      "offset": 4630,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 11 (manual address 4630)"
    },
    {
      "name": "Cell_Voltage_12",
      "offset": 4632,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 12 (manual address 4632)"
    },
    {
      "name": "Cell_Voltage_13",
      "offset": 4634,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 13 (manual address 4634)"
    },
    {
      "name": "Cell_Voltage_14",
      "offset": 4636,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 14 (manual address 4636)"
    },
    {
      "name": "Cell_Voltage_15",
      "offset": 4638,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 15 (manual address 4638)"
    },
    {
      "name": "Cell_Voltage_16",
      "offset": 4640,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 16 (manual address 4640)"
    },
    {
      "name": "Cell_Voltage_17",
      "offset": 4642,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 17 (manual address 4642)"
    },
    {
      "name": "Cell_Voltage_18",
      "offset": 4644,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 18 (manual address 4644)"
    },
    {
      "name": "Cell_Voltage_19",
      "offset": 4646,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 19 (manual address 4646)"
    },
    {
      "name": "Cell_Voltage_20",
      "offset": 4648,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 20 (manual address 4648)"
    },
    {
      "name": "Cell_Voltage_21",
      "offset": 4650,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 21 (manual address 4650)"
    },
    {
      "name": "Cell_Voltage_22",
      "offset": 4652,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 22 (manual address 4652)"
    },
    {
      "name": "Cell_Voltage_23",
      "offset": 4654,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 23 (manual address 4654)"
    },
    {
      "name": "Cell_Voltage_24",
      "offset": 4656,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 24 (manual address 4656)"
    },
    {
      "name": "Cell_Voltage_25",
      "offset": 4658,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 25 (manual address 4658)"
    },
    {
      "name": "Cell_Voltage_26",
      "offset": 4660,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 26 (manual address 4660)"
    },
    {
      "name": "Cell_Voltage_27",
      "offset": 4662,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 27 (manual address 4662)"
    },
    {
      "name": "Cell_Voltage_28",
      "offset": 4664,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 28 (manual address 4664)"
    },
    {
      "name": "Cell_Voltage_29",
      "offset": 4666,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 29 (manual address 4666)"
    },
    {
      "name": "Cell_Voltage_30",
      "offset": 4668,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 30 (manual address 4668)"
    },
    {
      "name": "Cell_Voltage_31",
      "offset": 4670,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Cell voltage, index 31 (manual address 4670)"
    },
    {
      "name": "Cell_Presence",
      "offset": 4672,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Cell presence bits (manual address 4672)"
    },
    {
      "name": "Cell_Voltage_Average",
      "offset": 4676,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Average cell voltage (manual address 4676)"
    },
    {
      "name": "Cell_Voltage_Max_Difference",
      "offset": 4678,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Maximum cell voltage difference (manual address 4678)"
    },
    {
      "name": "Power_Board_Temperature",
      "offset": 4746,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Power board temperature (manual address 4746)"
    },
    {
      "name": "Balance_Wire_Alarm_Bits",
      "offset": 4748,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Balance wire resistance alarm bits (manual address 4748)"
    },
    {
      "name": "Battery_Voltage",
      "offset": 4752,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Battery total voltage (manual address 4752)"
    },
    {
      "name": "Battery_Power",
      "offset": 4756,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mW",
      "description": "Battery power (manual address 4756)"
    },
    {
      "name": "Battery_Current",
      "offset": 4760,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Battery current (manual address 4760)"
    },
    {
      "name": "Battery_Temperature_1",
      "offset": 4764,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Battery temperature sensor 1 (manual address 4764)"
    },
    {
      "name": "Battery_Temperature_2",
      "offset": 4766,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Battery temperature sensor 2 (manual address 4766)"
    },
    {
      "name": "Alarm_Bits",
      "offset": 4768,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Alarm bits (manual address 4768)"
    },
    {
      "name": "Balance_Current",
      "offset": 4772,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Balance current (manual address 4772)"
    },
    {
      "name": "Remaining_Capacity",
      "offset": 4776,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mAh",
      "description": "Remaining capacity (manual address 4776)"
    },
    {
      "name": "Full_Charge_Capacity",
      "offset": 4780,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mAh",
      "description": "Actual battery capacity (manual address 4780)"
    },
    {
      "name": "Cycle_Count",
      "offset": 4784,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Cycle count (manual address 4784)"
    },
    {
      "name": "Cycle_Capacity",
      "offset": 4788,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "mAh",
      "description": "Total cycle capacity (manual address 4788)"
    },
    {
      "name": "User_Alarm",
      "offset": 4794,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "User level alarm word (manual address 4794)"
    },
    {
      "name": "Run_Time",
      "offset": 4796,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Run time (manual address 4796)"
    },
    {
      "name": "User_Alarm_2",
      "offset": 4802,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "User level alarm word 2 (manual address 4802)"
    },
    {
      "name": "Discharge_Overcurrent_Release_Time",
      "offset": 4804,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Discharge overcurrent protection release time (manual address 4804)"
    },
    {
      "name": "Discharge_Short_Circuit_Release_Time",
      "offset": 4806,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Discharge short circuit protection release time (manual address 4806)"
    },
    {
      "name": "Charge_Overcurrent_Release_Time",
      "offset": 4808,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Charge overcurrent protection release time (manual address 4808)"
    },
    {
      "name": "Charge_Short_Circuit_Release_Time",
      "offset": 4810,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Charge short circuit protection release time (manual address 4810)"
    },
    {
      "name": "Cell_Undervoltage_Release_Time",
      "offset": 4812,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Cell undervoltage protection release time (manual address 4812)"
    },
    {
      "name": "Cell_Overvoltage_Release_Time",
      "offset": 4814,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Cell overvoltage protection release time (manual address 4814)"
    },
    {
      "name": "Emergency_Switch_Time",
      "offset": 4820,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Emergency switch time (manual address 4820)"
    },
    {
      "name": "Discharge_Current_Correction",
      "offset": 4822,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Discharge current correction factor (manual address 4822)"
    },
    {
      "name": "Charge_Current_Sensor_Voltage",
      "offset": 4824,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Charge current sensor voltage (manual address 4824)"
    },
    {
      "name": "Discharge_Current_Sensor_Voltage",
      "offset": 4826,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mV",
      "description": "Discharge current sensor voltage (manual address 4826)"
    },
    {
      "name": "Battery_Voltage_Correction",
      "offset": 4828,
      "register_type": "float32",
      "register_area": "holding",
      "scale": 1,
      "description": "Battery voltage correction factor (manual address 4828)"
    },
    {
      "name": "Battery_Voltage_Small",
      "offset": 4836,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 0.01,
      "unit": "V",
      "description": "Battery voltage (16-bit) (manual address 4836)"
    },
    {
      "name": "Heating_Current",
      "offset": 4838,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 1,
      "unit": "mA",
      "description": "Heating current (manual address 4838)"
    },
    {
      "name": "System_Ticks",
      "offset": 4848,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "s",
      "description": "System run ticks (manual address 4848)"
    },
    {
      "name": "Battery_Temperature_3",
      "offset": 4856,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Battery temperature sensor 3 (manual address 4856)"
    },
    {
      "name": "Battery_Temperature_4",
      "offset": 4858,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Battery temperature sensor 4 (manual address 4858)"
    },
    {
      "name": "Battery_Temperature_5",
      "offset": 4860,
      "register_type": "int16",
      "register_area": "holding",
      "scale": 0.1,
      "unit": "degC",
      "description": "Battery temperature sensor 5 (manual address 4860)"
    },
    {
      "name": "Rtc_Ticks",
      "offset": 4864,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "RTC counter (manual address 4864)"
    },
    {
      "name": "Time_Enter_Sleep",
      "offset": 4872,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Time to enter sleep (manual address 4872)"
    },
    {
      "name": "Max_Min_Cell_Numbers",
      "offset": 4680,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Cell numbers with maximum and minimum voltage (manual address 4680)"
    },
    {
      "name": "Balance_State_And_Soc",
      "offset": 4774,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Balance state and state of charge (manual address 4774)"
    },
    {
      "name": "Soh_And_Precharge",
      "offset": 4792,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "State of health and precharge state (manual address 4792)"
    },
    {
      "name": "Charge_And_Discharge_State",
      "offset": 4800,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Charge and discharge state (manual address 4800)"
    },
    {
      "name": "Temp_Sensor_Flags_And_Heating",
      "offset": 4816,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Temperature sensor presence flags and heating state (manual address 4816)"
    },
    {
      "name": "Reserved_And_Charger_Plugged",
      "offset": 4846,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Charger plugged state (manual address 4846)"
    },
    {
      "name": "Pcl_Module_State",
      "offset": 4876,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Parallel current limiting module state (manual address 4876)"
    },
    {
      "name": "Accumulated_Run_Time",
      "offset": 5152,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "unit": "s",
      "description": "Accumulated run time (manual address 5152)"
    },
    {
      "name": "Power_On_Count",
      "offset": 5156,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Number of power-ons (manual address 5156)"
    },
    {
      "name": "Command_Shutdown",
      "offset": 5636,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Protection board shutdown command (manual address 5636)",
      "writable": true
    },
    {
      "name": "Command_Preset_Li_Ion",
      "offset": 5642,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "One-key setting for ternary lithium (LI-ION) (manual address 5642)",
      "writable": true
    },
    {
      "name": "Command_Preset_LiFePO4",
      "offset": 5644,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "One-key setting for LiFePO4 (manual address 5644)",
      "writable": true
    },
    {
      "name": "Command_Preset_Lto",
      "offset": 5646,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "One-key setting for lithium titanate (LTO) (manual address 5646)",
      "writable": true
    },
    {
      "name": "Command_Emergency_Start",
      "offset": 5648,
      "register_type": "uint16",
      "register_area": "holding",
      "scale": 1,
      "description": "Emergency start command (manual address 5648)",
      "writable": true
    },
    {
      "name": "Command_Time_Calibration",
      "offset": 5650,
      "register_type": "int32",
      "register_area": "holding",
      "scale": 1,
      "description": "Time calibration (manual address 5650)",
      "writable": true
    }
  ]
}